Select your language

List-Magnetik GmbH

List-Magnetik Magnetic Field Meters

 

From the question to the right device

Magnetic field measuring devices to measure residual magnetism

The earth's magnetic field is 0.2 A / cm strong. Just a little more residual magnetism on steel parts and chips will stick. Recognize the magnetic field around your workpiece.

MP-810

Magnetic Field Meter/Gaussmeter MP-810
 

MP-1000

Magnetic Field Meter/Gaussmeter MP-1000

MP-80

Residual Magnetic Field Meter MP-80
For measuring magnetic constant and alternating fields with an axial field probe or a transversal field probe
Model MP-810A: Axial field probe ø 8mm with a defined measuring distance of 2.0 mm
Model MP-810T: Transversal field probe 1.7 mm thick with 0.9 mm sensor distance.
  Magnetic field meter for measuring direct and alternating fields.

Applicable measuring probes:
Axial probes P-A2 and P-W2,
Transversal probes P-T2 and P-Z2.
Residual Magnetic Field Meter / Remanence Meter for the determination of residual magnetism on steel parts. Measuring probe: Axial field probe with a defined measuring distance of 2.0 mm from the surface.
more info   more info more info

Magnetic field measuring devices to measure the peak value

In order to detect the highest value of the magnetic field, the entire magnet must be examined. With the peak value memory you can be sure that you will not miss this point.

MP-810

Magnetic Field Meter/Gaussmeter MP-810

MP-4000

Magnetic Field Meter/Gaussmeter MP-4000

MP-1000

Magnetic Field Meter/Gaussmeter MP-1000

MP-80

Residual Magnetic Field Meter MP-80
For measuring magnetic constant and alternating fields with an axial field probe or a transversal field probe
Model MP-810A: Axial field probe ø 8mm with a defined measuring distance of 2.0 mm
Model MP-810T: Transversal field probe 1.7 mm thick with 0.9 mm sensor distance.
For professional measurement of direct and alternating fields.

Applicable measuring probes:
Axial probes PM2-A and PM4-A,
Transversal probes PM2-T, PM4-T, PM2-TR and PM4-TR.
Magnetic field meter for measuring direct and alternating fields.

Applicable measuring probes:
Axial probes P-A2 and P-W2,
Transversal probes P-T2 and P-Z2.
Residual Magnetic Field Meter / Remanence Meter for the determination of residual magnetism on steel parts. Measuring probe: Axial field probe with a defined measuring distance of 2.0 mm from the surface.
more info more info more info more info

Magnetic field measuring devices to measure the magnetic field on flat or curved material

for example on sheet metal, spheres, cuboids - wherever you can see the surface and place the probe on

MP-810

Magnetic Field Meter/Gaussmeter MP-810

MP-4000

Magnetic Field Meter/Gaussmeter MP-4000

MP-1000

Magnetic Field Meter/Gaussmeter MP-1000

MP-80

Residual Magnetic Field Meter MP-80
For measuring magnetic constant and alternating fields with an axial field probe or a transversal field probe

Model MP-810A
For professional measurement of direct and alternating fields.

With measuring probe PM2-A or PM4-A
Magnetic field meter for measuring direct and alternating fields.

With measuring probe P-A2
Residual Magnetic Field Meter / Remanence Meter for the determination of residual magnetism on steel parts. Measuring probe: Axial field probe with a defined measuring distance of 2.0 mm from the surface.
more info more info more info more info

Magnetic field measuring devices for measuring magnetic fields in gaps, notches, bores, on running surfaces

- in other words, in places that cannot be reached with the axial probe. Or if the measuring direction has to be transversal.

MP-810

Magnetic Field Meter/Gaussmeter MP-810

MP-4000

Magnetic Field Meter/Gaussmeter MP-4000

MP-1000

Magnetic Field Meter/Gaussmeter MP-1000
 
For measuring magnetic constant and alternating fields with an axial field probe or a transversal field probe

Model MP-810T
For professional measurement of direct and alternating fields.

With measuring probe PM2-T or PM4-T
Magnetic field meter for measuring direct and alternating fields.

With measuring probe P-T2
 
more info more info more info  

External probes for magnetic field measuring devices

The probe is attached to a 80 cm long cable. The probe is easy to replace, and the cable can also be replaced separately if it is defective. An external probe is advantageous if the result cannot be read directly on the integrated measuring device.
 

MP-4000

Magnetic Field Meter/Gaussmeter MP-4000

MP-1000

Magnetic Field Meter/Gaussmeter MP-1000
 
  For professional measurement of direct and alternating fields.

Applicable measuring probes:
Axial probes PM2-A and PM4-A,
Transversal probes PM2-T, PM4-T, PM2-TR and PM4-TR.
Magnetic field meter for measuring direct and alternating fields.

Applicable measuring probes:
Axial probes P-A2 and P-W2,
Transversal probes P-T2 and P-Z2.
 
  more info more info  

Magnetic field measuring devices with exactly 2 mm measuring distance

A de facto industry standard when measuring the magnetic field strength on ball bearings is a 2 mm distance between the sensor and the end of the axial probe. This means that measurement results for the customer and supplier can be compared. Because: the distance is a major factor in the measured values.

MP-810

Magnetic Field Meter/Gaussmeter MP-810

MP-4000

Magnetic Field Meter/Gaussmeter MP-4000

MP-1000

Magnetic Field Meter/Gaussmeter MP-1000

MP-80

Residual Magnetic Field Meter MP-80
For measuring magnetic constant and alternating fields with an axial field probe or a transversal field probe

Model MP-810A
For professional measurement of direct and alternating fields.

With measuring probe PM2-A or PM4-A
Magnetic field meter for measuring direct and alternating fields.

With measuring probe P-A2
Residual Magnetic Field Meter / Remanence Meter for the determination of residual magnetism on steel parts. Measuring probe: Axial field probe with a defined measuring distance of 2.0 mm from the surface.
more info more info more info more info

Magnetic field measuring devices for measuring units of measurement Gauss (Gs or G)

- instead of the standard A/cm, you can also measure in Gauss. Or in Oersted, an earlier unit in the CGS system of units. Both are equal in amount.

MP-810

Magnetic Field Meter/Gaussmeter MP-810

MP-4000

Magnetic Field Meter/Gaussmeter MP-4000

MP-1000

Magnetic Field Meter/Gaussmeter MP-1000

MP-80

Residual Magnetic Field Meter MP-80
For measuring magnetic constant and alternating fields with an axial field probe or a transversal field probe For professional measurement of direct and alternating fields.

Applicable measuring probes:
Axial probes PM2-A and PM4-A,
Transversal probes PM2-T, PM4-T, PM2-TR and PM4-TR.
Magnetic field meter for measuring direct and alternating fields.

Applicable measuring probes:
Axial probes P-A2 and P-W2,
Transversal probes P-T2 and P-Z2.
Residual Magnetic Field Meter / Remanence Meter for the determination of residual magnetism on steel parts. Measuring probe: Axial field probe with a defined measuring distance of 2.0 mm from the surface.
more info more info more info more info

Magnetic field measuring devices for measuring Tesla (T or Millitesla mT) units

- The Tesla is a derived SI unit of measurement for magnetic flux density and is named after Nikola Tesla.

MP-810

Magnetic Field Meter/Gaussmeter MP-810

MP-4000

Magnetic Field Meter/Gaussmeter MP-4000
 

MP-80

Residual Magnetic Field Meter MP-80
For measuring magnetic constant and alternating fields with an axial field probe or a transversal field probe For professional measurement of direct and alternating fields.

Applicable measuring probes:
Axial probes PM2-A and PM4-A,
Transversal probes PM2-T, PM4-T, PM2-TR and PM4-TR.
  Residual Magnetic Field Meter / Remanence Meter for the determination of residual magnetism on steel parts. Measuring probe: Axial field probe with a defined measuring distance of 2.0 mm from the surface.
more info more info   more info

Magnetic field measuring devices for measuring alternating magnetic fields (AC)

- Alternating magnetic fields are generated by coils through which alternating current flows. The magnetic field follows the level and direction of the applied voltage with a phase shift

MP-810

Magnetic Field Meter/Gaussmeter MP-810

MP-4000

Magnetic Field Meter/Gaussmeter MP-4000

MP-1000

Magnetic Field Meter/Gaussmeter MP-1000
 
For measuring magnetic constant and alternating fields with an axial field probe or a transversal field probe For professional measurement of direct and alternating fields.

Applicable measuring probes:
Axial probes PM2-A and PM4-A,
Transversal probes PM2-T, PM4-T, PM2-TR and PM4-TR.
Magnetic field meter for measuring direct and alternating fields.

Applicable measuring probes:
Axial probes P-A2 and P-W2,
Transversal probes P-T2 and P-Z2.
 
more info more info more info  

Magnetic field measuring devices for measuring crack tests

- an alternating magnetic field is generated by a coil, which induces eddy currents in the material to be examined. If the resulting alternating fields are homogeneous and constant, the material is OK. Cracks "swirl" the magnetic field; they can be recognized by cracks in the measured value.

MP-810

Magnetic Field Meter/Gaussmeter MP-810

MP-4000

Magnetic Field Meter/Gaussmeter MP-4000

MP-1000

Magnetic Field Meter/Gaussmeter MP-1000
 
For measuring magnetic constant and alternating fields with an axial field probe or a transversal field probe For professional measurement of direct and alternating fields.

Applicable measuring probes:
Axial probes PM2-A and PM4-A,
Transversal probes PM2-T, PM4-T, PM2-TR and PM4-TR.
Magnetic field meter for measuring direct and alternating fields.

Applicable measuring probes:
Axial probes P-A2 and P-W2,
Transversal probes P-T2 and P-Z2.
 
more info more info more info  

Statistical values

Evaluation of measurement series according to number, minimum, maximum, mean value and standard deviation

MP-810

Magnetic Field Meter/Gaussmeter MP-810

MP-4000

Magnetic Field Meter/Gaussmeter MP-4000
   
For measuring magnetic constant and alternating fields with an axial field probe or a transversal field probe For professional measurement of direct and alternating fields.

Applicable measuring probes:
Axial probes PM2-A and PM4-A,
Transversal probes PM2-T, PM4-T, PM2-TR and PM4-TR.
   
more info more info    

Data logger

Storage of measured values and statistical evaluation according to number, minimum, maximum, mean value and standard deviation

MP-810

Magnetic Field Meter/Gaussmeter MP-810

MP-4000

Magnetic Field Meter/Gaussmeter MP-4000
   
For measuring magnetic constant and alternating fields with an axial field probe or a transversal field probe

4000 values
For professional measurement of direct and alternating fields.

Applicable measuring probes:
Axial probes PM2-A and PM4-A,
Transversal probes PM2-T, PM4-T, PM2-TR and PM4-TR.

10000 values
   
more info more info    

Interfaces

Transfer of the data to a PC or mobile Android device

MP-810

Magnetic Field Meter/Gaussmeter MP-810

MP-4000

Magnetic Field Meter/Gaussmeter MP-4000
   
For measuring magnetic constant and alternating fields with an axial field probe or a transversal field probe

Via Bluetooth to Windows PC, Android, iOS
For professional measurement of direct and alternating fields.

Applicable measuring probes:
Axial probes PM2-A and PM4-A,
Transversal probes PM2-T, PM4-T, PM2-TR and PM4-TR.

Via Bluetooth to Windows PC, Android, iOS
   
more info more info    

Note on how to use

Magnetic field meters from List-Magnetik are suitable for measuring direct and alternating magnetic fields up to a maximum of 20 kHz with a measuring range from a minimum of 0.01 mT (= 10 µT) to a maximum of 5 T. These are fields with a strength of at least the earth's magnetic field.
However, they are not suitable for measuring high-frequency electromagnetic fields in the sense of an EMC test or electric fields in the range of a few µT.
There are special EMC meters on the market for this purpose, which we do not sell.