Angular Axial Probe P-W2 to measure magnetic fields with MP-1000 and MP-2000
The axial field probe measures the field along the longitudinal axis of the probe. The angled tip allows measurement in gaps.
Axial Field Probe P-A2 to measure magnetic fields with MP-1000 and MP-2000
The axial field probe measures the field along the longitudinal axis of the probe.
Axial Field Probe P-A4 to measure magnetic fields with MP-2000
The axial field probe measures the field along the longitudinal axis of the probe.
Axial Field Probe PM2-A to measure magnetic fields with MP-4000
The axial field probe measures the field along the longitudinal axis of the probe.
Axial Field Probe PM4-A to measure magnetic fields with MP-4000
The axial field probe measures the field along the longitudinal axis of the probe.
Calibration Base Plate FE to calibrate the Coating Thickness Meters on ferrous metals. By direct application, a zero calibration is carried out, and by the additional use of a calibration foil a two-point calibration.
Calibration Base Plate NFE to calibrate the Coating Thickness Meters on non-ferrous metals (aluminum). By direct application, a zero calibration is carried out, and by the additional use of a calibration foil a two-point calibration.
Calibration foil approx. 100 µm for two-point calibration of Coating Thickness Meters (other foil thicknesses on request)
Calibration foil approx. 300 µm for two-point calibration of Coating Thickness Meters (other foil thicknesses on request)
Calibration foil set with manufacturer's certificate for checking the calibration of coating thickness meters. The calibration foil set is supplied with 4 calibration foils in the range of 30-300 ?m and a ceramic calibration plate of 1000 ?m. The certificate is traceable to Physikalisch-Technische Bundesanstalt (PTB) Braunschweig.
A calibration standard is a reference magnet with which a measuring probe matched to it can be checked for accuracy by the user.
The calibration standard is only available as an accessory for a List-Magnetik magnetic field meter with flexible reed probe or angular axial probe (P-W2, P-Z2, P-Z4), not for devices of other manufacturers. When ordering, please let us know for which probe the calibration standard is to be used.
A calibration standard is a reference sample with which a Ferromaster permeability measuring device can be checked for its measuring accuracy.
A calibration standard is a reference sample with which a Ferromaster permeability measuring device can be checked for its measuring accuracy.
A calibration standard is a reference sample with which a Ferromaster permeability measuring device can be checked for its measuring accuracy.
A calibration standard is a reference magnet with which a measuring probe matched to it can be checked for accuracy by the user.
The calibration standard is only available as an accessory for a List-Magnetik magnetic field meter. When ordering, please specify the probe for which the calibration standard is to be used.
Charger for coating thickness meters MEGA-CHECK (MEGA-CHECK Basic / Profi / Master, since 2007) and magnetic field meter MP-2000. Supplied with 3 rechargeable 1.2V NiMH batteries
The List-Magnetik MEGA-CHECK series of coating thickness meters can be used to connect many specialized probes. Applications at particularly small openings, thick layers and small measuring points are therefore possible without any problems.
MEGA-CHECK Basic is the standard device for rapid on-site measurement.
You can connect many specialized digital probes to the List-Magnetik MEGA-CHECK DX coating thickness meter. Applications on particularly small openings, on thick coatings and on small measuring points are thus easily possible. Special functions such as scan measurement for rough surfaces and duplex measurement for galvanized and additionally coated steel round off the performance spectrum.
The LIST-MAGNETIK MEGA-CHECK series of coating thickness meters can be used to connect many specialized probes. Applications at particularly small openings, thick layers and small measuring points are therefore possible without problems.
MEGA-CHECK Master is a high-end device with easy to use functions for many different applications. In addition to the performance of MEGA-CHECK Profi, MEGA-CHECK Master has a scan function for determining the thickness of the coating on rough or blasted surfaces.
Furthermore, there is a duplex function for the precise determination of the individual layer thickness for measurements of insulating layers on galvanized steel parts.
In the case of continuous measurement of the layer thickness, the analogous representation of the measured value profile proves to be an important support.